Diagnostic Error Code FRU/Action
014-013-XXX
014-014-XXXParallel port Control
Signal/Loopback test failure
1. System board
014-015-XXXParallel port External Loopback
failure
1. Wrap plug
2. System board
014-027-XXXParallel port Configuration/Setup
error
1. Run Setup, enable port
2. Flash the system
3. System board
014-03X-XXX
014-04X-XXXParallel port failure
1. System board
014-195-XXXParallel port Test aborted by user
1. Information
2. Re-start the test, if necessary
014-196-XXXParallel port test halt, error
threshold exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
014-197-XXXParallel port test warning
1. Make sure the component that is called out is
connected and/or enabled
2. Re-run test
3. Component that is called out in warning statement
4. Component under test
014-198-XXXParallel port test aborted
1. If a component is called out, make sure it is
connected and/or enabled
2. Flash the system and re-test
3. Go to the Undetermined problems section
014-199-XXXParallel port test failed, cause
unknown
1. Go to the Undetermined problems section
2. Flash the system and re-test
3. Replace component under function test
014-2XX-XXX
014-3XX-XXXParallel port failure
1. External parallel device
2. System board
015-000-XXXUSB port Interface Test Passed
1. No action
015-001-XXXUSB port Presence
1. Remove USB device(s) and re-test
2. System board
015-002-XXXUSB port Timeout
1. Remove USB device(s) and re-test
2. System board
Chapter 1. IBM PC Enhanced Diagnostics error codes 9