Ibm DS8000 Manual de usuario Pagina 1

Busca en linea o descarga Manual de usuario para Hardware Ibm DS8000. IBM DS8000 User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 450
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
ibm.com/redbooks
Front cover
The IBM TotalStorage Storage
DS8000 Series:s:
Concepts and ArchitectureArchitecture
Cathy Warrick
Olivier Alluis
Werner Bauer
Heinz Blaschek
Andre Fourie
Juan Antonio Garay
Torsten Knobloch
Donald C Laing
Christine O’Sullivan
Stu S Preacher
Torsten Rothenwaldt
Tetsuroh Sano
Jing Nan Tang
Anthony Vandewerdt
Alexander Warmuth
Roland Wolf
Advanced features and performance
breakthrough with POWER5 technology
Configuration flexibility with LPAR
and virtualization
Highly scalable solutions for
on demand storage
Vista de pagina 0
1 2 3 4 5 6 ... 449 450

Indice de contenidos

Pagina 1 - DS8000 Series:s:

ibm.com/redbooksFront coverThe IBM TotalStorage Storage DS8000 Series:s:Concepts and ArchitectureArchitectureCathy WarrickOlivier AlluisWerner BauerHe

Pagina 2

viii DS8000 Series: Concepts and Architecture12.4.1 Workload characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 3

78 DS8000 Series: Concepts and ArchitectureOn the ESS 800 the spare creation policy was to have four DDMs on each SSA loop for each DDM type. This me

Pagina 4

Chapter 4. RAS 794.6.6 Disk scrubbingThe DS8000 will periodically read all sectors on a disk. This is designed to occur without any interference wit

Pagina 5

80 DS8000 Series: Concepts and Architecture4.7.1 Building power lossThe DS8000 uses an area of server memory as non-volatile storage (NVS). This are

Pagina 6

Chapter 4. RAS 81data from NVS memory to a variably sized disk area to preserve that data until power is restored. However, the EPO switch does not a

Pagina 7

82 DS8000 Series: Concepts and ArchitectureWhile the installation process described above may seem complex, it will not require a great deal of user

Pagina 8

© Copyright IBM Corp. 2005. All rights reserved. 83Chapter 5. Virtualization conceptsThis chapter describes virtualization concepts as they apply to t

Pagina 9

84 DS8000 Series: Concepts and Architecture5.1 Virtualization definitionIn our fast-paced world, where you have to react quickly to changing busines

Pagina 10

Chapter 5. Virtualization concepts 85Figure 5-1 Storage Facility virtualization5.3 The abstraction layers for disk virtualizationIn this chapter,

Pagina 11 - Contents ix

86 DS8000 Series: Concepts and ArchitectureFigure 5-2 Physical layer as the base for virtualizationFigure 5-2 shows the physical layer on which vir

Pagina 12

Chapter 5. Virtualization concepts 87Figure 5-3 Array siteAs you can see from Figure 5-3, array sites span loops. Four DDMs are taken from loop 1 a

Pagina 13 - Contents xi

Contents ixChapter 15. Open systems support and software . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31915.1 Open systems support .

Pagina 14

88 DS8000 Series: Concepts and ArchitectureFigure 5-4 Creation of an arraySo, an array is formed using one array site, and while the array could be

Pagina 15

Chapter 5. Virtualization concepts 89a Model 1, and a Model 1 has 1113 cylinders which is about 0.94 GB. The extent size of a CKD rank therefore was

Pagina 16

90 DS8000 Series: Concepts and ArchitectureThe DS Storage Manager GUI guides the user to use the same RAID types in an extent pool. As such, when an

Pagina 17

Chapter 5. Virtualization concepts 915.3.5 Logical volumesA logical volume is composed of a set of extents from one extent pool. On a DS8000 up to 6

Pagina 18

92 DS8000 Series: Concepts and ArchitectureFigure 5-7 Allocation of a CKD logical volumeFigure 5-7 shows how a logical volume is allocated with a C

Pagina 19

Chapter 5. Virtualization concepts 93Figure 5-8 Creation of an FB LUNiSeries LUNsiSeries LUNs are also composed of fixed block 1 GB extents. There

Pagina 20

94 DS8000 Series: Concepts and Architectureallocation of logical volumes across ranks to improve performance, except for the case in which the logica

Pagina 21

Chapter 5. Virtualization concepts 95created and determines the LSS that it is associated with. The 256 possible logical volumes associated with an L

Pagina 22

96 DS8000 Series: Concepts and ArchitectureAddress groupsAddress groups are created automatically when the first LSS associated with the address grou

Pagina 23

Chapter 5. Virtualization concepts 97server access to logical volumes, the DS8000 introduced the concept of host attachments and volume groups.Host a

Pagina 24

x DS8000 Series: Concepts and ArchitectureHBA and operating system settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 25

98 DS8000 Series: Concepts and ArchitectureFB logical volumes may be defined in one or more volume groups. This allows a LUN to be shared by host HBA

Pagina 26

Chapter 5. Virtualization concepts 99This new virtualization concept provides for much more flexibility. Logical volumes can dynamically be created a

Pagina 27

100 DS8000 Series: Concepts and ArchitectureFigure 5-13 Optimal placement of data5.4 Benefits of virtualizationThe DS8000 physical and logical arc

Pagina 28

Chapter 5. Virtualization concepts 101򐂰 Any mix of CKD or FB addresses in 4096 address groups.򐂰 Increased logical volume size:– CKD: 55.6 GB (65520 c

Pagina 29

102 DS8000 Series: Concepts and Architecture

Pagina 30

© Copyright IBM Corp. 2005. All rights reserved. 103Chapter 6. IBM TotalStorage DS8000 model overview and scalabilityThis chapter provides an overview

Pagina 31

104 DS8000 Series: Concepts and Architecture6.1 DS8000 highlightsThe DS8000 is a member of the DS product family. It offers disk storage servers wit

Pagina 32

Chapter 6. IBM TotalStorage DS8000 model overview and scalability 105In the following sections, we describe these models further:1. DS8100 Model 921T

Pagina 33

106 DS8000 Series: Concepts and ArchitectureThe DS8100 Model 921 can connect to one expansion frame. This expansion frame is called a Model 92E. Figu

Pagina 34

Chapter 6. IBM TotalStorage DS8000 model overview and scalability 107Both models provide the following features:򐂰 Two processor complexes with pSerie

Pagina 35

Contents xiOnline resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 414How

Pagina 36

108 DS8000 Series: Concepts and Architecture– Up to 32 host adapters (HAs) with four 2 Gbps Fibre Channel ports on each HA. Each HA can be freely con

Pagina 37

Chapter 6. IBM TotalStorage DS8000 model overview and scalability 109Table 6-1 DS8000 model comparisonDepending on the DDM sizes, which can be diff

Pagina 38

110 DS8000 Series: Concepts and ArchitectureTable 6-2 Comparison of models for capacityAdding DDMsA significant benefit of the DS8000 series is the

Pagina 39

Chapter 6. IBM TotalStorage DS8000 model overview and scalability 111Linear-scalable architectureThe following two figures illustrate how you can rea

Pagina 40

112 DS8000 Series: Concepts and ArchitectureFigure 6-7 4-way model componentsThese two figures describe the main components of the I/O controller f

Pagina 41

Chapter 6. IBM TotalStorage DS8000 model overview and scalability 113򐂰 The DS8000 series has a longer life cycle than other storage devices.6.3.3 Mo

Pagina 42

114 DS8000 Series: Concepts and Architecture

Pagina 43

© Copyright IBM Corp. 2005. All rights reserved. 115Chapter 7. Copy ServicesIn this chapter, we describe the architecture and functions of Copy Servic

Pagina 44

116 DS8000 Series: Concepts and Architecture7.1 Introduction to Copy ServicesCopy Services is a collection of functions that provide disaster recove

Pagina 45

Chapter 7. Copy Services 117See Figure 7-1 for an illustration of FlashCopy concepts.Figure 7-1 FlashCopy conceptsWhen a FlashCopy operation is inv

Pagina 46

xii DS8000 Series: Concepts and Architecture

Pagina 47

118 DS8000 Series: Concepts and Architecture– If the backup data is not copied yet, first the backup data is copied to the target volume, and after t

Pagina 48

Chapter 7. Copy Services 119Figure 7-2 Incremental FlashCopyIn the Incremental FlashCopy operations:1. At first, you issue full FlashCopy with the

Pagina 49

120 DS8000 Series: Concepts and ArchitectureFigure 7-3 Data Set FlashCopyMultiple Relationship FlashCopyMultiple Relationship FlashCopy allows a so

Pagina 50

Chapter 7. Copy Services 121Consistency Group FlashCopyConsistency Group FlashCopy allows you to freeze (temporarily queue) I/O activity to a LUN or

Pagina 51

122 DS8000 Series: Concepts and ArchitectureA more detailed discussion of the concept of data consistency and how to manage the Consistency Group ope

Pagina 52

Chapter 7. Copy Services 123Persistent FlashCopyPersistent FlashCopy allows the FlashCopy relationship to remain even after the copy operation comple

Pagina 53

124 DS8000 Series: Concepts and ArchitectureFigure 7-7 Metro MirrorGlobal Copy (PPRC-XD)Global Copy copies data non-synchronously and over longer d

Pagina 54

Chapter 7. Copy Services 125Figure 7-8 Global CopyGlobal Mirror (Asynchronous PPRC)Global Mirror provides a long-distance remote copy feature acros

Pagina 55

126 DS8000 Series: Concepts and Architecture򐂰 Efficient synchronization of the local and remote sites with support for failover and failback modes, h

Pagina 56

Chapter 7. Copy Services 127Figure 7-10 How Global Mirror worksThe A volumes at the local site are the production volumes and are used as Global Co

Pagina 57

© Copyright IBM Corp. 2005. All rights reserved. xiiiNoticesThis information was developed for products and services offered in the U.S.A. IBM may not

Pagina 58

128 DS8000 Series: Concepts and ArchitectureThe data at the remote site is current within 3 to 5 seconds, but this recovery point (RPO) depends on th

Pagina 59

Chapter 7. Copy Services 129Figure 7-11 z/OS Global Mirrorz/OS Metro/Global Mirror (3-site z/OS Global Mirror and Metro Mirror) This mirroring capa

Pagina 60

130 DS8000 Series: Concepts and ArchitectureFigure 7-12 z/OS Metro/Global Mirror7.2.4 Comparison of the Remote Mirror and Copy functionsIn this se

Pagina 61

Chapter 7. Copy Services 131Global Copy (PPRC-XD)򐂰 DescriptionGlobal Copy is a function for continuous copy without data consistency.򐂰 AdvantagesIt c

Pagina 62

132 DS8000 Series: Concepts and Architecture򐂰 Considerations:When the link bandwidth capability is exceeded with a heavy workload, the RPO might grow

Pagina 63

Chapter 7. Copy Services 133򐂰Operation 3In the Consistency Group operation, data consistency means this sequence is always kept in the backup data.An

Pagina 64

134 DS8000 Series: Concepts and Architecture.Figure 7-13 Consistency Group: Example1Because of the time lag for Consistency Group operations, some

Pagina 65

Chapter 7. Copy Services 135Figure 7-14 Consistency Group: Example 2In all cases, if each write operation is dependent, Consistency Group can keep

Pagina 66

136 DS8000 Series: Concepts and ArchitectureFigure 7-15 Consistency Group: Example.3In this case, the copy created by the Consistency Group operati

Pagina 67

Chapter 7. Copy Services 137from these interfaces, S-HMC communicates with each server in the storage units via the Ethernet network. Therefore, the

Pagina 68

xiv DS8000 Series: Concepts and ArchitectureTrademarksThe following terms are trademarks of the International Business Machines Corporation in the Un

Pagina 69

138 DS8000 Series: Concepts and Architecture7.3.3 DS Command-Line Interface (DS CLI)The IBM TotalStorage DS Command-Line Interface (CLI) helps enabl

Pagina 70

Chapter 7. Copy Services 139IBM will support IBM TotalStorage Multiple Device Manager (MDM) for the DS8000 under the IBM TotalStorage Productivity Ce

Pagina 71

140 DS8000 Series: Concepts and Architecture

Pagina 72

© Copyright IBM Corp. 2005. All rights reserved. 141Part 3 Planning and configurationIn this part we present an overview of the planning and configura

Pagina 73

142 DS8000 Series: Concepts and Architecture

Pagina 74

© Copyright IBM Corp. 2005. All rights reserved. 143Chapter 8. Installation planningThis chapter discusses various physical considerations and prepara

Pagina 75

144 DS8000 Series: Concepts and Architecture8.1 General considerationsSuccessful installation of a DS8000 requires careful planning. The main consid

Pagina 76

Chapter 8. Installation planning 1452. Ensure that your loading dock, receiving area, and elevators can safely support the packaged weight and dimens

Pagina 77

146 DS8000 Series: Concepts and ArchitectureInstalling on raised or nonraised floorsYou can install your DS8000 storage units on a raised or nonraise

Pagina 78

Chapter 8. Installation planning 147Table 8-2 The DS8000 dimensions2. Calculate the total area that is needed for the model configuration by adding

Pagina 79

© Copyright IBM Corp. 2005. All rights reserved. xvPrefaceThis IBM® Redbook describes the IBM TotalStorage® DS8000 series of storage servers, its arch

Pagina 80

148 DS8000 Series: Concepts and ArchitectureYou can use the following power controls through the DS Storage Manager (running on the Management Consol

Pagina 81

Chapter 8. Installation planning 149Use the following feature codes when you specify the input voltage for your base or expansion model: 򐂰 9090 AC in

Pagina 82

150 DS8000 Series: Concepts and ArchitectureCooling the storage complex Adequate airflow needs to be maintained to ensure effective cooling. You can

Pagina 83

Chapter 8. Installation planning 151Channel adapter has four ports. Each port has a unique worldwide port name (WWPN). You can configure the port to

Pagina 84

152 DS8000 Series: Concepts and Architectureor point-to-point topologies. With Fibre Channel adapters that are configured for FICON, the storage unit

Pagina 85

Chapter 8. Installation planning 153CNT (INRANGE):http://www.cnt.com/ibm/McDATA: http://www.mcdata.com/ibm/Cisco:http://www.cisco.com/go/ibm/storageC

Pagina 86

154 DS8000 Series: Concepts and Architecture8.5.2 Remote support connection requirements You must meet the requirements for the modem and for an out

Pagina 87

Chapter 8. Installation planning 155You should also keep the following considerations in mind:򐂰 Fibre channel SANs can provide the capability to inte

Pagina 88

156 DS8000 Series: Concepts and Architecture

Pagina 89

© Copyright IBM Corp. 2005. All rights reserved. 157Chapter 9. Configuration planningThis chapter discusses planning considerations related to impleme

Pagina 90

xvi DS8000 Series: Concepts and ArchitectureWerner Bauer is a certified IT specialist in Germany. He has 25 years of experience in storage software a

Pagina 91

158 DS8000 Series: Concepts and Architecture9.1 Configuration planning overviewWhen installing a DS8000 disk system, various physical requirements n

Pagina 92

Chapter 9. Configuration planning 159as shown. To interconnect two DS8000 base frames, FC1190 would provide a pair of 31m Ethernet cables to connect

Pagina 93

160 DS8000 Series: Concepts and Architecture9.2.2 S-HMC software componentsThe S-HMC consists of the following software functions:򐂰 Remote services򐂰

Pagina 94

Chapter 9. Configuration planning 161customer server and can be used for the configuration of a DS8000 series system at initial installation or for r

Pagina 95

162 DS8000 Series: Concepts and ArchitectureSystem and partition managementCustomer access to the S-HMC is provided to allow the management of option

Pagina 96

Chapter 9. Configuration planning 163򐂰TCP/IP interface network mask (for example, 255.255.254.0).򐂰 If you plan to use a Domain Name Server (DNS) to r

Pagina 97

164 DS8000 Series: Concepts and ArchitectureFigure 9-3 S-HMC network topologyIn this configuration, capabilities exist to execute remote services s

Pagina 98

Chapter 9. Configuration planning 165request an IP connection, or if the modem is unavailable, will use voice phone or e-mail to request an IP connec

Pagina 99

166 DS8000 Series: Concepts and ArchitectureSecurity mechanism 3 - Login securityWhen the network connection and session are established, the IBM Ser

Pagina 100 - Hot plugable DDMs

Chapter 9. Configuration planning 167Regardless of the type of connectivity (VPN or ftp), no customer data is transmitted to IBM.9.3 DS8000 licensed

Pagina 101 - 4.7 Power and cooling

Preface xviiworking on System/34, System/38™, AS/400®, and iSeries™. Most recently, he has focused on iSeries Storage, and at the beginning of 2004,

Pagina 102 - 4.7.1 Building power loss

168 DS8000 Series: Concepts and ArchitectureTable 9-3 Operating environment license feature codesLicensed functions are activated and enforced with

Pagina 103 - 4.8 Microcode updates

Chapter 9. Configuration planning 169Copy functions, you specify the feature code that represents the physical capacity to authorize for the function

Pagina 104 - 4.10 Summary

170 DS8000 Series: Concepts and ArchitectureTable 9-7 Remote Mirror for zSeries (RMZ) feature codes9.3.5 Parallel Access Volumes (2244 Model PAV)T

Pagina 105 - Virtualization concepts

Chapter 9. Configuration planning 171Figure 9-4 User authorize to FlashCopy 25 TB of CKD dataAS illustrated in Figure 9-5 on page 172, the user dec

Pagina 106

172 DS8000 Series: Concepts and ArchitectureFigure 9-5 User authorize to FlashCopy 45 TB of data with a license scope of ALLFor PTC and RMC, you ma

Pagina 107 - LPAR Hypervisor

Chapter 9. Configuration planning 173Figure 9-6 Remote Mirror and CopyGlobal Mirror requires both RMC and PTC functions. Both primary and secondary

Pagina 108 - Storage enclosure pair

174 DS8000 Series: Concepts and ArchitectureActivation refers to the retrieval and installation of the feature activation code into the DS8000 system

Pagina 109 - Loop 1 Loop 2

Chapter 9. Configuration planning 175DS8000 adopts a virtualization concept, which was introduced in Chapter 5, “Virtualization concepts” on page 83.

Pagina 110 - 5.3.3 Ranks

176 DS8000 Series: Concepts and ArchitectureFigure 9-8 FB RAID rank capacityFor example, if you configure a RAID-5 rank with 146 GB DDMs with a spa

Pagina 111 - 5.3.4 Extent pools

Chapter 9. Configuration planning 1779.4.3 Sparing examplesThis section provides some examples for configuring each rank according to the rule of sp

Pagina 113 - 5.3.5 Logical volumes

xviii DS8000 Series: Concepts and ArchitectureFront row - Cathy, Torsten R, Torsten K, Andre, Toni, Werner, Tetsuroh. Back row - Roland, Olivier, Ant

Pagina 114

178 DS8000 Series: Concepts and ArchitectureFigure 9-10 Sparing example 2: RAID-10 - All same capacity, same RPMIn Figure 9-10, four RAID-10 arrays

Pagina 115 - 2.9 GB LUN

Chapter 9. Configuration planning 179Figure 9-11 Sparing example 3: RAID-5 - Different capacity, same RPMFigure 9-11 illustrates an intermix config

Pagina 116

180 DS8000 Series: Concepts and ArchitectureFigure 9-12 Sparing example 4: RAID-5 - Different capacity, different RPMFigure 9-12 illustrates anothe

Pagina 117 - DB2-test

Chapter 9. Configuration planning 181A Standby CoD disk set contains 16 disk drives of the same capacity and RPM (10000 or 15000 RPM). With this offe

Pagina 118 - 5.3.7 Volume access

182 DS8000 Series: Concepts and ArchitectureFigure 9-13 DDM to DA mapping (2-way model)Model 921 can have four DA pairs and 12 disk enclosure pairs

Pagina 119 - Volume group

Chapter 9. Configuration planning 183Figure 9-14 DDM to DA Mapping (4-way model)Model 922 can have eight DA pairs and 20 disk enclosure pairs.There

Pagina 120

184 DS8000 Series: Concepts and Architecture9.5.1 Operating system mirroringLogical volume mirroring (LVM) and Veritas Volume Manager have little or

Pagina 121 - 5.3.9 Placement of data

Chapter 9. Configuration planning 185򐂰Minimal host application outages.The disadvantages of remote copy technologies are:򐂰 The same storage device ty

Pagina 122 - Host LVM volume

186 DS8000 Series: Concepts and ArchitectureFigure 9-15 Different data migration methodsSee Chapter 14, “Data migration in zSeries environments” on

Pagina 123

Chapter 9. Configuration planning 1879.6.1 Disk MagicAn IBM representative or an IBM Business Partner can model your workload using Disk Magic befor

Pagina 124

Preface xixGerry CoteIBM SouthfieldDari DurnasIBM TampaLinda Benhase, Jerry Boyle, Helen Burton, John Elliott, Kenneth Hallam, Lloyd Johnson, Carl J

Pagina 125

188 DS8000 Series: Concepts and ArchitectureFor example, in the zSeries environment, the RMF™ RAID rank report can be used to investigate RAID rank s

Pagina 126 - Model Naming Conventions

© Copyright IBM Corp. 2005. All rights reserved. 189Chapter 10. The DS Storage Manager - logical configurationIn this chapter, the following topics ar

Pagina 127 - 6.1.2 DS8100 Model 921

190 DS8000 Series: Concepts and Architecture10.1 Configuration hierarchy, terminology, and conceptsThe DS Storage Manager provides a powerful, flexi

Pagina 128

Chapter 10. The DS Storage Manager - logical configuration 191Figure 10-1 Diagram of hosts and host attachment groups򐂰 In Figure 10-1 we show three

Pagina 129

192 DS8000 Series: Concepts and ArchitectureOne set of host definitions may be used for multiple storage images, storage units, and storage complexes

Pagina 130 - 6.2 Model comparison

Chapter 10. The DS Storage Manager - logical configuration 193Figure 10-2 An extent pool containing 2 volumesFigure 10-2 is an example of one exten

Pagina 131 - 6.3 Designed for scalability

194 DS8000 Series: Concepts and Architecture򐂰 There are thresholds that warn you when you are nearing the end of space utilization on the extent pool

Pagina 132 - Future plan

Chapter 10. The DS Storage Manager - logical configuration 195򐂰They contain one or more host attachments from different hosts and one or more LUNs. T

Pagina 133 - 2-way I/O controllers

196 DS8000 Series: Concepts and ArchitectureFigure 10-4 Example of volume groups, LUNs and host attachment definitionsIn Figure 10-4 we show three

Pagina 134 - 4-way I/O controllers

Chapter 10. The DS Storage Manager - logical configuration 197Figure 10-5 shows an example of the relationship between LSSs, extent pools, and volume

Pagina 135 - Model Conversions

xx DS8000 Series: Concepts and Architecture

Pagina 136

198 DS8000 Series: Concepts and Architecture– FB LSSs’ definitions are configured during the volume creation.򐂰 LSSs have no predetermined relation to

Pagina 137 -

Chapter 10. The DS Storage Manager - logical configuration 19910.1.2 Summary of the DS Storage Manager logical configuration stepsIt is our recommen

Pagina 138

200 DS8000 Series: Concepts and ArchitectureFigure 10-7 View of the raw DDM to LUN relationshipRaw or physical DDM layerAt the very top of Figure 1

Pagina 139

Chapter 10. The DS Storage Manager - logical configuration 201Figure 10-8 Diagram of how parity is striped across physical disksRank layer At this

Pagina 140

202 DS8000 Series: Concepts and ArchitectureFigure 10-9 Recommended logical configuration steps10.2 Introducing the GUI and logical configuration

Pagina 141

Chapter 10. The DS Storage Manager - logical configuration 203Figure 10-10 Entering the URL using the TCP/IP address for the S-HMCIn Figure 10-10,

Pagina 142

204 DS8000 Series: Concepts and ArchitectureWeb browser running directly to the on-board S-HMC, or in a remote machine connected into the user’s netw

Pagina 143

Chapter 10. The DS Storage Manager - logical configuration 205support. A view of the fully expanded Real-time manager menu choices is shown in Figure

Pagina 144

206 DS8000 Series: Concepts and ArchitectureFigure 10-14 The fully expanded Simulated manager menu choicesThe following items should be considered

Pagina 145

Chapter 10. The DS Storage Manager - logical configuration 207Figure 10-15 User administration panelClick Go to advance to the panel shown in Figur

Pagina 146

© Copyright IBM Corp. 2005. All rights reserved. 1Part 1 IntroductionIn this part we introduce the IBM TotalStorage DS8000 series and its key features

Pagina 147

208 DS8000 Series: Concepts and ArchitectureFigure 10-17 View of the information center10.2.3 Navigating the GUIKnowing what icons, radio buttons,

Pagina 148

Chapter 10. The DS Storage Manager - logical configuration 2092. Icon 2 will hide the black banner across the top of the screen, again to increase th

Pagina 149

210 DS8000 Series: Concepts and Architecture2 Deselect All3 Show Filter Row4 Clear All Filters5 Edit Sort6 Clear All Sorts򐂰The caret button (numbe

Pagina 150

Chapter 10. The DS Storage Manager - logical configuration 211In the example shown in Figure 10-22, the radio button is checked to allow specific hos

Pagina 151

212 DS8000 Series: Concepts and ArchitectureFigure 10-24 The Create Storage Complex panel, with the Nickname and Description definedDo not click Cr

Pagina 152

Chapter 10. The DS Storage Manager - logical configuration 213Figure 10-25 The General storage unit information panelFill in the required fields as

Pagina 153

214 DS8000 Series: Concepts and ArchitectureFigure 10-26 View of the Defined licensed function panelFill in the fields shown in Figure 10-26 with t

Pagina 154

Chapter 10. The DS Storage Manager - logical configuration 215Figure 10-27 View of Specify DDM packs panel, with the Quantity and DDM type added5.

Pagina 155

216 DS8000 Series: Concepts and Architecture10.3.3 Configuring the logical host systemsTo create a logical host for the storage unit that you just c

Pagina 156

Chapter 10. The DS Storage Manager - logical configuration 217Figure 10-31 View of the General host information panelClick Next to advance to the D

Pagina 157

2 DS8000 Series: Concepts and Architecture

Pagina 158

218 DS8000 Series: Concepts and ArchitectureClick Add, and the Define host ports panel will be updated with the new information as shown in Figure 10

Pagina 159

Chapter 10. The DS Storage Manager - logical configuration 219The screen will advance to the Specify storage image parameters section shown in Figure

Pagina 160

220 DS8000 Series: Concepts and ArchitectureFigure 10-36 The Definition method panelFrom the Definition method panel, if you choose Create arrays a

Pagina 161

Chapter 10. The DS Storage Manager - logical configuration 221Click Next to advance to the Add arrays to ranks panel shown in Figure 10-38.If you cli

Pagina 162

222 DS8000 Series: Concepts and ArchitectureFigure 10-39 The Definition method panelThe extent pools are given either a server 0 or server 1 affini

Pagina 163

Chapter 10. The DS Storage Manager - logical configuration 223Choose the extent pool from which you wish to configure the volumes, as shown in Figure

Pagina 164

224 DS8000 Series: Concepts and ArchitectureIt is here that the volume will take on the LSS numbering affinity.You can give the volume a unique name

Pagina 165

Chapter 10. The DS Storage Manager - logical configuration 225Figure 10-44 The Define volume group properties filled out4. Select the host attachme

Pagina 166

226 DS8000 Series: Concepts and Architecture5. Select volumes on the Select volumes for group panel shown in Figure 10-46.Figure 10-46 The Select v

Pagina 167

Chapter 10. The DS Storage Manager - logical configuration 2274. Click Go.5. Click OK.10.3.10 Creating CKD LCUsUnder Simulated Manager, zSeries, per

Pagina 168

© Copyright IBM Corp. 2005. All rights reserved. 3Chapter 1. Introduction to the DS8000 seriesThis chapter provides an overview of the features, funct

Pagina 169

228 DS8000 Series: Concepts and Architecture12.Under the Define alias assignments panel, do the following:a. Click the check box next to the LCU numb

Pagina 170

Chapter 10. The DS Storage Manager - logical configuration 229Figure 10-49 View of the WWNN in the General panel10.4 SummaryIn this chapter we hav

Pagina 171

230 DS8000 Series: Concepts and Architecture

Pagina 172

© Copyright IBM Corp. 2005. All rights reserved. 231Chapter 11. DS CLIThis chapter provides an introduction to the DS Command-Line Interface (DS CLI),

Pagina 173

232 DS8000 Series: Concepts and Architecture11.1 IntroductionThe IBM TotalStorage DS Command-Line Interface (the DS CLI) is a software package that

Pagina 174

Chapter 11. DS CLI 233򐂰Manage host access to volumes򐂰 Configure host adapter portsThe DS CLI can be used to invoke the following Copy Services functi

Pagina 175

234 DS8000 Series: Concepts and ArchitectureThe exact install process doesn’t really vary by operating system. It consists of:1. The DS CLI CD is pla

Pagina 176

Chapter 11. DS CLI 235Figure 11-1 Command flow for ESS 800 Copy Services commandsA CS server is now able to manage up to eight F20s and ESS 800s. T

Pagina 177

236 DS8000 Series: Concepts and ArchitectureFigure 11-2 DS CLI Copy Services command flowDS8000 split networkOne thing that you may notice about Fi

Pagina 178

Chapter 11. DS CLI 237Figure 11-3 Command flow for the DS6000For the DS6000, it is possible to install a second network interface card within the D

Pagina 179

4 DS8000 Series: Concepts and Architecture1.1 The DS8000, a member of the TotalStorage DS familyIBM has a wide range of product offerings that are b

Pagina 180

238 DS8000 Series: Concepts and ArchitectureFigure 11-4 CLI co-existenceStorage managementESS CLI commands that are used to perform storage managem

Pagina 181

Chapter 11. DS CLI 23911.6 User securityThe DS CLI software must authenticate with the S-HMC or CS Server before commands can be issued. An initial

Pagina 182

240 DS8000 Series: Concepts and Architecturecsadmin op_copy_servicesexit status of dscli = 0C:\Program Files\IBM\dscli>It is also possible to inc

Pagina 183

Chapter 11. DS CLI 241contain only DS CLI commands. This is because all commands in the script are executed by a single instance of the DS CLI interp

Pagina 184

242 DS8000 Series: Concepts and ArchitectureExample 11-8 Use of the help -l commanddscli> help -l mkflashmkflash [ { -help|-h|-? } ] [-fullid] [

Pagina 185

Chapter 11. DS CLI 243echo A DS CLI application error occurred.goto end:level5echo An authentication error occurred. Check the userid and password.go

Pagina 186

244 DS8000 Series: Concepts and Architecture# The following command checks the status of the rankslsrank -dev IBM.2107-9999999# The following command

Pagina 187

Chapter 11. DS CLI 245Migration considerationsIf your environment is currently using the ESS CS CLI to manage Copy Services on your model 800s, you c

Pagina 188

246 DS8000 Series: Concepts and ArchitectureFigure 11-6 A portion of the tasks listed by using the GUIIn Example 11-12, the list task command is us

Pagina 189

Chapter 11. DS CLI 247Figure 11-7 Using the GUI to get the contents of a FlashCopy taskIt makes more sense, however, to use the ESS CLI show task c

Pagina 190

Chapter 1. Introduction to the DS8000 series 5The DS8000 is a flexible and extendable disk storage subsystem because it is designed to add and adapt

Pagina 191

248 DS8000 Series: Concepts and ArchitectureTable 11-3 Converting a FlashCopy task to DS CLISo to create the DS CLI command, simply read down the t

Pagina 192

Chapter 11. DS CLI 24911.10.4 Using DS CLI commands via a single command or scriptHaving translated a saved task into a DS CLI command, you may now

Pagina 193

250 DS8000 Series: Concepts and Architecturepwfile: passwd# Default target Storage Image ID# If the -dev parameter is needed in a command then it wil

Pagina 194

Chapter 11. DS CLI 251anthony@aixsrv:/opt/ibm/dscli >The command can also be placed into a file and that file made executable. An example is shown

Pagina 195

252 DS8000 Series: Concepts and Architecture

Pagina 196

© Copyright IBM Corp. 2005. All rights reserved. 253Chapter 12. Performance considerationsThis chapter discusses early performance considerations rega

Pagina 197

254 DS8000 Series: Concepts and Architecture12.1 What is the challenge?In recent years we have seen an increasing speed in developing new storage se

Pagina 198

Chapter 12. Performance considerations 255Figure 12-1 Host server and storage server comparison: Balanced throughput challengeThe challenge is obvi

Pagina 199

256 DS8000 Series: Concepts and Architecture12.2.1 SSA backend interconnectionThe Storage Serial Architecture (SSA) connectivity with the SSA loops

Pagina 200

Chapter 12. Performance considerations 257relatively small logical volumes, we ran out of device numbers to address an entire LSS. This happens even

Pagina 201

6 DS8000 Series: Concepts and Architecture1.2.1 Hardware overviewThe hardware has been optimized to provide enhancements in terms of performance, co

Pagina 202

258 DS8000 Series: Concepts and ArchitectureFigure 12-2 Switched FC-AL disk subsystemPerformance is enhanced since both DAs connect to the switched

Pagina 203

Chapter 12. Performance considerations 259Figure 12-3 High availability and increased bandwidth connecting both DA to two logical loopsThese two sw

Pagina 204

260 DS8000 Series: Concepts and Architecture12.3.2 Fibre Channel device adapterThe DS8000 still relies on eight DDMs to form a RAID-5 or a RAID-10 a

Pagina 205

Chapter 12. Performance considerations 261ports per HA and up to 16 HAs in the smallest family member of the DS8000 series, the DS8100, you can confi

Pagina 206

262 DS8000 Series: Concepts and ArchitectureFigure 12-6 Standard pSeries POWER5 p570 2-way SMP processor complexes for DS8100-921Figure 12-7 provid

Pagina 207

Chapter 12. Performance considerations 263complex, server 1. This affinity is established at creation of an extent pool. For details see Chapter 10,

Pagina 208

264 DS8000 Series: Concepts and Architectureswitch has two ports to connect to the next switch pair with 16 DDMs when vertically growing within a DS8

Pagina 209

Chapter 12. Performance considerations 26512.4.1 Workload characteristicsThe answers to questions like how many host connections do I need?, how muc

Pagina 210

266 DS8000 Series: Concepts and ArchitectureAll disks in the storage subsystem should have roughly the equivalent utilization. Any disk that is used

Pagina 211

Chapter 12. Performance considerations 267Figure 12-10 Spreading data across ranksThe stripe sizeEach striped logical volume that is created by the

Pagina 212

Chapter 1. Introduction to the DS8000 series 7Storage Hardware Management Console (S-HMC) for the DS8000The DS8000 offers a new integrated management

Pagina 213

268 DS8000 Series: Concepts and Architecture12.4.6 Determining the number of paths to a LUNWhen configuring the IBM DS8000 for an open systems host,

Pagina 214

Chapter 12. Performance considerations 269Figure 12-11 Dual port host attachment12.5 Performance and sizing considerations for z/OSHere we discuss

Pagina 215

270 DS8000 Series: Concepts and ArchitectureFigure 12-12 DS8100 frontend connectivity example - partial viewNote that this figure only indicates th

Pagina 216

Chapter 12. Performance considerations 271the I/O rate and highly sequential read operations for the MB/sec numbers. They also vary depending on the

Pagina 217

272 DS8000 Series: Concepts and ArchitectureIt is not just the pure cache size which accounts for good performance figures. Economical use of cache,

Pagina 218

Chapter 12. Performance considerations 273Another example, with four ESS F20s each with eight FICON channels, might collapse into about 20 FICON port

Pagina 219

274 DS8000 Series: Concepts and ArchitectureUse Capacity Magic to find out about usable disk capacity. For information on this internal IBM tool, con

Pagina 220

Chapter 12. Performance considerations 275Figure 12-13 Extent pool affinity to processor complex with one extent pool for each rankFigure 12-12 als

Pagina 221

276 DS8000 Series: Concepts and ArchitectureFigure 12-14 Extent pool affinity to processor complex with pooled ranks in two extent poolsAgain what

Pagina 222

Chapter 12. Performance considerations 277Figure 12-15 Mix of extent poolsCreate two general extent pools for all the average workload and the majo

Pagina 223

International Technical Support OrganizationThe IBM TotalStorage DS8000 Series:Concepts and ArchitectureApril 2005SG24-6452-00

Pagina 224

8 DS8000 Series: Concepts and Architectureworkloads, and with different operating environments, within a single physical DS8000 storage subsystem. Th

Pagina 225

278 DS8000 Series: Concepts and Architecture12.6 SummaryThis high performance processor complex configuration is the base for a maximum of host I/O

Pagina 226

© Copyright IBM Corp. 2005. All rights reserved. 279Part 4 Implementation and management in the z/OS environmentvironmentIn this part we discuss consi

Pagina 227

280 DS8000 Series: Concepts and Architecture

Pagina 228

© Copyright IBM Corp. 2005. All rights reserved. 281Chapter 13. zSeries software enhancementsThis chapter discusses z/OS, z/VM, z/VSE and Transaction

Pagina 229

282 DS8000 Series: Concepts and Architecture13.1 Software enhancements for the DS8000A number of enhancements have been introduced into the z/OS, z/

Pagina 230

Chapter 13. zSeries software enhancements 283has the capability to scale up to 63.75K devices. With the current support, we may have CPU or spin lock

Pagina 231

284 DS8000 Series: Concepts and ArchitectureToday control unit single point of failure information is specified in a table and must be updated for ea

Pagina 232

Chapter 13. zSeries software enhancements 285Figure 13-1 Display output from DEVSERV QDASD commandFigure 13-2 displays output from the DEVSERV PATH

Pagina 233

286 DS8000 Series: Concepts and ArchitectureLISTDATA COUNT The RAID RANK counters report will not be available on the DS8000. These counters are bein

Pagina 234

Chapter 13. zSeries software enhancements 287Figure 13-4 shows the LISTDATA COUNTS report output for the DS8000. This report shows the Segment Pool n

Pagina 235

Chapter 1. Introduction to the DS8000 series 9IBM TotalStorage FlashCopyFlashCopy can help reduce or eliminate planned outages for critical applicati

Pagina 236

288 DS8000 Series: Concepts and ArchitectureLISTDATA STATUSFigure 13-5 displays the output from the LISTDATA STATUS report. The output is the same, e

Pagina 237

Chapter 13. zSeries software enhancements 289SETCACHEThe DASD fast write attributes cannot be changed to OFF status on the DS8000. Figure 13-7 on pag

Pagina 238

290 DS8000 Series: Concepts and Architecture13.2.9 Migration considerationsA DS8000 will be supported as an IBM 2105 for z/OS systems without the DF

Pagina 239

Chapter 13. zSeries software enhancements 29113.5 TPF enhancementsTPF is an IBM platform for high volume, online transaction processing. It is used

Pagina 240

292 DS8000 Series: Concepts and Architecture

Pagina 241

© Copyright IBM Corp. 2005. All rights reserved. 293Chapter 14. Data migration in zSeries environmentsThis chapter describes several methods for migra

Pagina 242

294 DS8000 Series: Concepts and Architecture14.1 Define migration objectives in z/OS environmentsData migration is an important activity that needs

Pagina 243

Chapter 14. Data migration in zSeries environments 295“To avoid a single point of failure in a sysplex, IBM recommends that, for all couple data sets

Pagina 244

296 DS8000 Series: Concepts and ArchitectureNote that some data set types cannot grow beyond 64K tracks. When coming from 3390-3 and staying with 50,

Pagina 245

Chapter 14. Data migration in zSeries environments 297see on a single 3390-3. Or, to put it differently, we may see on a single volume as many concur

Pagina 246

10 DS8000 Series: Concepts and ArchitectureIBM TotalStorage Global Mirror (Asynchronous PPRC)Global Mirror copying provides a two-site extended dista

Pagina 247

298 DS8000 Series: Concepts and Architecture14.1.4 Summary of data migration objectivesTo summarize the objective of data migration, it might be fea

Pagina 248

Chapter 14. Data migration in zSeries environments 299parameter. When the target volume is larger than the source volume it is usually necessary to a

Pagina 249

300 DS8000 Series: Concepts and ArchitectureFigure 14-2 Piper for z/OS environment configurationCurrently this server is a Multiprise 3000, which c

Pagina 250

Chapter 14. Data migration in zSeries environments 301Most of these benefits also apply to migration efforts controlled by the customer when utilizin

Pagina 251

302 DS8000 Series: Concepts and ArchitectureThis requires an adequate bandwidth for the connectivity between the disk storage servers to the system i

Pagina 252

Chapter 14. Data migration in zSeries environments 303To utilize the advantage of PPRC with concurrent data migration on a physical volume level from

Pagina 253

304 DS8000 Series: Concepts and Architectureimpact to the application write I/Os at the source storage subsystems from where we migrate the data. Thi

Pagina 254

Chapter 14. Data migration in zSeries environments 305 DEVICE DESCRIPTOR = 0A ADDITIONAL

Pagina 255

306 DS8000 Series: Concepts and Architectureare back to the TSO CQUERY command which does not need any additional JCL statements and does not care wh

Pagina 256

Chapter 14. Data migration in zSeries environments 307Again all these approaches to utilize microcode-based mirroring capabilities require the right

Pagina 257

Chapter 1. Introduction to the DS8000 series 11physically located (installed) inside the DS8000 subsystem and can automatically monitor the state of

Pagina 258

308 DS8000 Series: Concepts and Architecture LIDD(IN001,IN002,IN003) - DELETE PURGE CATALOG SELECTMU

Pagina 259

Chapter 14. Data migration in zSeries environments 309Figure 14-7 SMS Storage Groups - migration source environmentTo explain this approach, Figure

Pagina 260

310 DS8000 Series: Concepts and ArchitectureExample 14-7 Execute SMS modify commands through pre-defined job//DISNEW JOB ,' DISABLE NEW &a

Pagina 261

Chapter 14. Data migration in zSeries environments 311 CDS Name . . . . . : SYS1.DFSMS.SCDS Storage Group N

Pagina 262

312 DS8000 Series: Concepts and ArchitectureExample 14-11 Indicate SMS volume status change for all connected system imagesSMS VOLUME STATUS ALTER

Pagina 263

Chapter 14. Data migration in zSeries environments 313To show how powerful, meaningful naming conventions for VOLSERs might be combined with the sele

Pagina 264

314 DS8000 Series: Concepts and Architecture//SYSPRINT DD DUMMY //SYSUT1 DD DSN=WB.MIGRATE.CNTL(

Pagina 265

Chapter 14. Data migration in zSeries environments 315When a level is reached where no data moves any more because the remaining data sets are in use

Pagina 266

316 DS8000 Series: Concepts and Architectureimpact when the actual switch uses P/DAS, although it is quicker and easier to allow for a brief service

Pagina 267

© Copyright IBM Corp. 2005. All rights reserved. 317Part 5 Implementation and management in the open systems environmentIn this part we discuss consid

Pagina 268

12 DS8000 Series: Concepts and ArchitectureDS8000 compared to DS6000DS6000 and DS8000 now offer an enterprise continuum of storage solutions. All cop

Pagina 269

318 DS8000 Series: Concepts and Architecture

Pagina 270

© Copyright IBM Corp. 2005. All rights reserved. 319Chapter 15. Open systems support and softwareIn this chapter we describe how the DS8000 fits into

Pagina 271

320 DS8000 Series: Concepts and Architecture15.1 Open systems supportThe scope of open systems support of the new DS8000 model is based on that of t

Pagina 272

Chapter 15. Open systems support and software 321updated frequently. Therefore it is advisable to visit these resources regularly and check for updat

Pagina 273

322 DS8000 Series: Concepts and ArchitectureQLogic maintains a page that lists all the HBAs, drivers, and firmware versions that are supported for at

Pagina 274

Chapter 15. Open systems support and software 323򐂰Some legacy operating systems and operating system versions were dropped from the support matrix. T

Pagina 275

324 DS8000 Series: Concepts and Architecture򐂰 Novell Netware򐂰 VMware 2.5.0򐂰 SuSE SLES915.2 Subsystem Device DriverTo ensure maximum availability mos

Pagina 276

Chapter 15. Open systems support and software 32515.3 Other multipathing solutionsSome operating systems come with native multipathing software, for

Pagina 277

326 DS8000 Series: Concepts and Architecturecommand will be passed directly to the S-HMC for immediate execution. The return code of the DS CLI progr

Pagina 278

Chapter 15. Open systems support and software 327As a component of the IBM TotalStorage Productivity Center, Multiple Device Manager is designed to r

Pagina 279

Chapter 1. Introduction to the DS8000 series 13The DS CLI is described in detail in Chapter 11, “DS CLI” on page 231.DS Open application programming

Pagina 280

328 DS8000 Series: Concepts and Architecture15.5.1 Device ManagerThe Device Manager (DM) builds on the IBM Director technology. It uses the Service

Pagina 281

Chapter 15. Open systems support and software 32915.5.2 TPC for DiskTPC for Disk, formerly known as MDM Performance Manager, provides the following

Pagina 282

330 DS8000 Series: Concepts and ArchitectureThe Volume Performance Advisor is an automated tool to help the storage administrator pick the best possi

Pagina 283

Chapter 15. Open systems support and software 331the DS8000 Storage Hardware Management Console for the execution of the commands. The commands allow

Pagina 284

332 DS8000 Series: Concepts and Architecture

Pagina 285

© Copyright IBM Corp. 2005. All rights reserved. 333Chapter 16. Data migration in the open systems environmentIn this chapter we discuss important con

Pagina 286

334 DS8000 Series: Concepts and Architecture16.1 IntroductionThe term data migration has a very diverse scope. We use it here solely to describe the

Pagina 287

Chapter 16. Data migration in the open systems environment 335We describe the most common methods in the next section. Be aware that, in a heterogene

Pagina 288

336 DS8000 Series: Concepts and ArchitectureReasons against using these methods could include:򐂰 Different methods are necessary for different data ty

Pagina 289

Chapter 16. Data migration in the open systems environment 337This method also requires the disruption of applications writing to the data for the co

Pagina 290

14 DS8000 Series: Concepts and Architectureoffer the most value to the customers. On the list of possible applications are, for example, Backup/Recov

Pagina 291

338 DS8000 Series: Concepts and Architecture򐂰 Mirror data for higher availability and migrationThe LUNs provided by the DS8000 appear to the LVM as p

Pagina 292

Chapter 16. Data migration in the open systems environment 339Figure 16-5 Migration using backup and restoreThe major disadvantage is again the dis

Pagina 293

340 DS8000 Series: Concepts and ArchitectureMetro Mirror and Global CopyFrom a local data migration point of view both methods are on par with each o

Pagina 294

Chapter 16. Data migration in the open systems environment 34116.2.3 IBM Piper migrationPiper is a hardware and software solution to move data betwe

Pagina 295

342 DS8000 Series: Concepts and Architecture16.2.4 Other migration applicationsThere are a number of applications available from other vendors that

Pagina 296

© Copyright IBM Corp. 2005. All rights reserved. 343Appendix A. Open systems operating systems specificsIn this appendix, we describe the particular i

Pagina 297

344 DS8000 Series: Concepts and ArchitectureGeneral considerationsIn this section we cover some topics that are not specific to a single operating sy

Pagina 298

Appendix A. Open systems operating systems specifics 345the data, even if this pool spans several ranks. If possible, the extents for one logical vol

Pagina 299

346 DS8000 Series: Concepts and ArchitectureThe output reports the following:򐂰 The %tm_act column indicates the percentage of the measured interval t

Pagina 300

Appendix A. Open systems operating systems specifics 347Example: A-3 SAR Sample Output# sar -u 2 5AIX aixtest 3 4 001750154C00 2/5/0317:58:15 %usr

Pagina 301

Chapter 1. Introduction to the DS8000 series 15reduce device queue delays. This is achieved by defining multiple addresses per volume. With Dynamic P

Pagina 302

348 DS8000 Series: Concepts and ArchitectureOther publicationsApart from the DS8000 Host Systems Attachment Guide, SC26-7628, there are two redbooks

Pagina 303

Appendix A. Open systems operating systems specifics 349 Device Specific.(ZB)...C2D3.91A1 Device Specific.(YL)...U1.13-P1-I1/Q1

Pagina 304

350 DS8000 Series: Concepts and ArchitecturePath# Adapter/Hard Disk State Mode Select Errors 0 fscsi2/hdisk17

Pagina 305

Appendix A. Open systems operating systems specifics 351http://publib16.boulder.ibm.com/pseries/en_US/aixbman/admnconc/hotplug_mgmt.htm#mpioconceptsT

Pagina 306

352 DS8000 Series: Concepts and ArchitectureRefer to the manpages of the MPIO commands for more information.LVM configurationIn AIX, all storage is m

Pagina 307

Appendix A. Open systems operating systems specifics 353Direct I/OAn alternative I/O technique called Direct I/O bypasses the Virtual Memory Manager

Pagina 308

354 DS8000 Series: Concepts and ArchitectureThe DS8000 requires the following i5 I/O adapters to attach directly to an i5 AIX partition:򐂰 0611 Direct

Pagina 309

Appendix A. Open systems operating systems specifics 355------------------------------------------------------------------------ #MBs #opns #rds

Pagina 310

356 DS8000 Series: Concepts and Architecture avg 13.97180 min 0.00004 max 57.54421 sdev 11.78066time to next req(msec): avg 8

Pagina 311

Appendix A. Open systems operating systems specifics 357Existing reference materialThere is a lot of information available that helps you set up your

Pagina 312

16 DS8000 Series: Concepts and Architecture

Pagina 313

358 DS8000 Series: Concepts and ArchitectureThe zSeries connectivity support page lists all supported storage devices and SAN components that can be

Pagina 314

Appendix A. Open systems operating systems specifics 359Each SCSI device can have up to 15 partitions, which are represented by the special device fi

Pagina 315

360 DS8000 Series: Concepts and ArchitectureAfter creating the device files you may have to change their owner, group, and file permission settings t

Pagina 316

Appendix A. Open systems operating systems specifics 361򐂰SDD, which creates a persistent relationship between a DS8000 volume and a vpath device rega

Pagina 317

362 DS8000 Series: Concepts and ArchitectureExample: A-12 Sample /etc/modules.confscsi_hostadapter aic7xxxscsi_hostadapter1 aic7xxxscsi_hostadapter

Pagina 318

Appendix A. Open systems operating systems specifics 363Example A-14 shows the SCSI disk assignment after one more DS8000 volume is added.Example: A-

Pagina 319

364 DS8000 Series: Concepts and Architecture򐂰 2787 2 Gigabit Fibre Channel Disk Controller PCI-XFor more information on OS/400 support for DS8000, pl

Pagina 320

Appendix A. Open systems operating systems specifics 365Example: A-17 Sample /proc/scsi/qla2300/x knox:~ # cat /proc/scsi/qla2300/2QLogic PCI to Fi

Pagina 321

366 DS8000 Series: Concepts and ArchitectureMicrosoft Windows 2000/2003DS8000 supports FC attachment to Microsoft Windows 2000/2003 servers. For deta

Pagina 322

Appendix A. Open systems operating systems specifics 367– With Windows 2003, MSCS uses target resets. See the Microsoft technical article Microsoft W

Pagina 323

© Copyright IBM Corp. 2005. All rights reserved. 17Part 2 ArchitectureIn this part we describe various aspects of the DS8000 series architecture. Thes

Pagina 324

368 DS8000 Series: Concepts and ArchitectureFor a detailed description of VDS, refer to the Microsoft Windows Server 2003 Virtual Disk Service Techni

Pagina 325

Appendix A. Open systems operating systems specifics 369Instead of writing a special OpenVMS driver, it has been decided to handle this in the DS8000

Pagina 326

370 DS8000 Series: Concepts and Architecture򐂰 Every FC volume must have a UDID that is unique throughout the OpenVMS cluster that accesses the volume

Pagina 327

Appendix A. Open systems operating systems specifics 371causes subsequent read operations to fail, which is the signal to the shadow driver to execut

Pagina 328

372 DS8000 Series: Concepts and Architecture

Pagina 329

© Copyright IBM Corp. 2005. All rights reserved. 373Appendix B. Using DS8000 with iSeriesIn this appendix, the following topics are discussed:򐂰 Suppor

Pagina 330

374 DS8000 Series: Concepts and ArchitectureSupported environmentNot all hardware and software combinations for OS/400 support the DS8000. This secti

Pagina 331

Appendix B. Using DS8000 with iSeries 375When creating the logical volumes for use with OS/400, you will see that in almost every case, the OS/400 de

Pagina 332

376 DS8000 Series: Concepts and ArchitectureAdding volumes to iSeries configurationOnce the logical volumes have been created and assigned to the hos

Pagina 333

Appendix B. Using DS8000 with iSeries 3774. When adding disk units to a configuration, you can add them as empty units by selecting Option 2 or you c

Pagina 334

© Copyright International Business Machines Corporation 2005. All rights reserved.Note to U.S. Government Users Restricted Rights -- Use, duplication

Pagina 335

18 DS8000 Series: Concepts and Architecture

Pagina 336

378 DS8000 Series: Concepts and ArchitectureFigure B-5 Confirm Add Units7. Depending on the number of units you are adding, this step could take so

Pagina 337

Appendix B. Using DS8000 with iSeries 3792. Expand the iSeries to which you wish to add the logical volume and sign on to that server as shown in Fig

Pagina 338

380 DS8000 Series: Concepts and ArchitectureFigure B-9 SST Signon5. Right-click Disk Pools and select New Disk Pool as shown in Figure B-10 on page

Pagina 339

Appendix B. Using DS8000 with iSeries 381Figure B-11 New disk pool - welcome7. On the New Disk Pool dialog shown in Figure B-12, select Primary fro

Pagina 340

382 DS8000 Series: Concepts and ArchitectureFigure B-13 Confirm disk pool configuration9. Now you need to add disks to the new disk pool. On the Ad

Pagina 341

Appendix B. Using DS8000 with iSeries 383Figure B-15 Choose the disks to add to the Disk Pool11.A confirmation screen appears as shown in Figure B-

Pagina 342

384 DS8000 Series: Concepts and ArchitectureFigure B-17 New Disk Pool Summary13.Take note of and respond to any message dialogs which appear. After

Pagina 343

Appendix B. Using DS8000 with iSeries 38515.The new Disk Pool can be seen on iSeries Navigator Disk Pools in Figure B-20.Figure B-20 New Disk Pool

Pagina 344

386 DS8000 Series: Concepts and ArchitectureMultipathMultipath support was added for external disks in V5R3 of i5/OS (also known as OS/400 V5R3). Unl

Pagina 345

Appendix B. Using DS8000 with iSeries 387Figure B-22 Single points of failureWhen implementing multipath, you should provide as much redundancy as

Pagina 346

© Copyright IBM Corp. 2005. All rights reserved. 19Chapter 2. ComponentsThis chapter describes the components used to create the DS8000. This chapter

Pagina 347

388 DS8000 Series: Concepts and Architecture򐂰 2787 2 Gigabit Fibre Channel Disk Controller PCI-XBoth can be used for multipath and there is no requir

Pagina 348

Appendix B. Using DS8000 with iSeries 3893. Option 8, Add units to ASPs and balance data.You will then be presented with a panel similar to Figure B-

Pagina 349

390 DS8000 Series: Concepts and ArchitectureAdding volumes to iSeries using iSeries NavigatorThe iSeries Navigator GUI can be used to add volumes to

Pagina 350

Appendix B. Using DS8000 with iSeries 391Figure B-28 New Disk Pool shown on iSeries NavigatorTo see the logical volume, as shown in Figure B-29, ex

Pagina 351

392 DS8000 Series: Concepts and ArchitectureManaging multipath volumes using iSeries NavigatorAll units are initially created with a prefix of DD. As

Pagina 352

Appendix B. Using DS8000 with iSeries 393Figure B-31 Selecting properties for a multipath logical unitYou will then see the General Properties tab

Pagina 353

394 DS8000 Series: Concepts and ArchitectureFigure B-32 Multipath logical unit propertiesTo see the other paths to this unit, click the Connections

Pagina 354

Appendix B. Using DS8000 with iSeries 395Figure B-33 Multipath connectionsMultipath rules for multiple iSeries systems or partitionsWhen you use mu

Pagina 355

396 DS8000 Series: Concepts and ArchitectureDisk unit connections might be missing for a variety of reasons, but especially if one of the preceding r

Pagina 356

Appendix B. Using DS8000 with iSeries 397Figure B-34 Process for sizing external storagePlanning for arrays and DDMsIn general, although it is poss

Pagina 357

20 DS8000 Series: Concepts and Architecture2.1 FramesThe DS8000 is designed for modular expansion. From a high-level view there appear to be three t

Pagina 358

398 DS8000 Series: Concepts and Architecturesome benefit in larger cache sizes. However, in general, with large iSeries main memory sizes, OS/400 Exp

Pagina 359

Appendix B. Using DS8000 with iSeries 399Recommended number of ranksAs a general guideline, you may consider 1500 disk operations/sec for an average

Pagina 360

400 DS8000 Series: Concepts and ArchitectureConnecting via SAN switchesWhen connecting DS8000 systems to iSeries via switches, you should plan that I

Pagina 361

Appendix B. Using DS8000 with iSeries 401Figure B-35 Using Metro Mirror to migrate from ESS to DS8000The same setup can also be used if the ESS LUN

Pagina 362

402 DS8000 Series: Concepts and Architecturedown time associated with removing a disk unit. This will keep new allocations away from the marked units

Pagina 363

Appendix B. Using DS8000 with iSeries 403Copy Services for iSeriesDue to OS/400 having a single level storage, it is not possible to copy some disk u

Pagina 364

404 DS8000 Series: Concepts and Architecturestorage) being copied, only the application resides in an IASP and in the event of a disaster, the target

Pagina 365

Appendix B. Using DS8000 with iSeries 405For more information on running AIX in an i5 partition, refer to the i5 Information Center at:򐂰 http://publi

Pagina 366

406 DS8000 Series: Concepts and Architecture

Pagina 367

© Copyright IBM Corp. 2005. All rights reserved. 407Appendix C. Service and support offeringsThis appendix provides information about the service offe

Pagina 368

Chapter 2. Components 21Between the disk enclosures and the processor complexes are two Ethernet switches, a Storage Hardware Management Console (an

Pagina 369

408 DS8000 Series: Concepts and ArchitectureIBM Web sites for service offeringsIBM Global Services (IGS) and the IBM Systems Group can offer comprehe

Pagina 370

Appendix C. Service and support offerings 409The IBM Piper hardware assisted migration in the zSeries environment is described in this redbook in “Da

Pagina 371

410 DS8000 Series: Concepts and Architecture򐂰 Unplanned outages (disaster recovery, testing a disaster)It simplifies the disaster recovery implementa

Pagina 372

Appendix C. Service and support offerings 411Figure 16-9 Example of the Supported Product List (SPL) from the IBM Support Line

Pagina 373

412 DS8000 Series: Concepts and Architecture

Pagina 374

© Copyright IBM Corp. 2005. All rights reserved. 413Related publicationsThe publications listed in this section are considered particularly suitable f

Pagina 375

414 DS8000 Series: Concepts and ArchitectureOnline resourcesThese Web sites and URLs are also relevant as further information sources:򐂰 IBM Disk Stor

Pagina 376

Related publications 415How to get IBM RedbooksYou can search for, view, or download Redbooks, Redpapers, Hints and Tips, draft publications and Add

Pagina 377

416 DS8000 Series: Concepts and Architecture

Pagina 378

© Copyright IBM Corp. 2005. All rights reserved. 417IndexSymbols 151, 298, 335, 368AAAL 36–37, 256benefits 37address groups 96, 196Advanced C

Pagina 379

22 DS8000 Series: Concepts and ArchitectureFigure 2-2 Rack operator panelYou will note that there is not a power on/off switch on the operator pane

Pagina 380

418 DS8000 Series: Concepts and Architecturehot plugable 78layer 200device adapter see DADFSMSdss 298, 307DFSMShsm 308disk drive set 7disk

Pagina 381

Index 419OELopen systems 150, 320ordering licensed functions 170p5 570 21, 27PAVperformance 14, 186, 253placement of data 99planning 344

Pagina 382

420 DS8000 Series: Concepts and ArchitectureFlashCopy to a Remote Mirror primary 9frames 20base 20expansion 21ftp offload option 166GGDPS

Pagina 383

Index 421LLCU 196licensed functions 167ordering 170scenarios 174Linux 356/proc pseudo file system 364issues 358managing multiple paths

Pagina 384

422 DS8000 Series: Concepts and Architecturedata placement 265Disk Magic 186–187ESCON 256FICON 256hot spot avoidance 188I/O priority queuin

Pagina 385

Index 423RIO-G 29RMC 123, 169comparison of functions 130Global Copy 124Global Mirror 125Metro Mirror 123RMF 289RMZ 169RPC 39RPO

Pagina 386

424 DS8000 Series: Concepts and ArchitecturevolumesCKD 91VSEESA 315WWindows Server 2003VDS supportWWNN 228WWPN 348XXRC see z/OS Global Mirror

Pagina 387

(0.5” spine)0.475”<->0.873”250 <-> 459 pagesThe IBM TotalStorage DS8000 Series: Concepts and ArchitectureDS8000 Series: Concepts and Archi

Pagina 388

DS8000 Series: Concepts and ArchitectureDS8000 Series: Concepts and Architecture

Pagina 390

Chapter 2. Components 23use fast-write, in which the data is written to volatile memory on one complex and persistent memory on the other complex. Th

Pagina 391

®SG24-6452-00 ISBN 0738492205INTERNATIONAL TECHNICALSUPPORTORGANIZATIONBUILDING TECHNICAL INFORMATION BASED ON PRACTICAL EXPERIENCEIBM Redbooks are de

Pagina 392

24 DS8000 Series: Concepts and ArchitectureIf you can view Figure 2-3 on page 23 in color, you can use the colors as indicators of how the DS8000 har

Pagina 393

Chapter 2. Components 25SARC basically attempts to determine four things:򐂰 When data is copied into the cache.򐂰 Which data is copied into the cache.򐂰

Pagina 394

26 DS8000 Series: Concepts and ArchitectureFigure 2-4 Cache lists of the SARC algorithm for random and sequential dataTo follow workload changes, t

Pagina 395

Chapter 2. Components 27For details on the server hardware used in the DS8000, refer to IBM p5 570 Technical Overview and Introduction, REDP-9117, av

Pagina 396

© Copyright IBM Corp. 2005. All rights reserved. iiiContentsNotices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 397

28 DS8000 Series: Concepts and ArchitectureFigure 2-5 Processor complexProcessor memoryThe DS8100 Model 921 offers up to 128 GB of processor memory

Pagina 398

Chapter 2. Components 29prevent any data loss without operating system or firmware involvement. Non-critical environmental events are also logged and

Pagina 399

30 DS8000 Series: Concepts and ArchitectureFigure 2-7 I/O enclosuresEach I/O enclosure has the following attributes:򐂰 4U rack-mountable enclosure

Pagina 400

Chapter 2. Components 31integrity it supports metadata creation and checking. The device adapter design is shown in Figure 2-8.Figure 2-8 DS8000 de

Pagina 401

32 DS8000 Series: Concepts and ArchitectureFigure 2-9 DS8000 disk enclosureNon-switched FC-AL drawbacksIn a standard FC-AL disk enclosure all of th

Pagina 402

Chapter 2. Components 33These problems are solved with the switched FC-AL implementation on the DS8000.Switched FC-AL advantagesThe DS8000 uses switc

Pagina 403

34 DS8000 Series: Concepts and ArchitectureFigure 2-12 Disk enclosure switched connectionsDS8000 switched FC-AL implementationFor a more detailed l

Pagina 404

Chapter 2. Components 35Figure 2-13 DS8000 switched disk expansionExpansionExpansion enclosures are added in pairs and disks are added in groups of

Pagina 405

36 DS8000 Series: Concepts and ArchitectureThe intention is to only have four spares per DA pair, but this number may increase depending on DDM inter

Pagina 406

Chapter 2. Components 37the array is placed on each loop. If the disk enclosures were fully populated with DDMs, there would be four array sites.Figu

Pagina 407

iv DS8000 Series: Concepts and Architecture2.4.2 Disk enclosures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 408

38 DS8000 Series: Concepts and ArchitectureThe ESCON adapter in the DS8000 is a dual ported host adapter for connection to older zSeries hosts that d

Pagina 409

Chapter 2. Components 39The card itself is PCI-X 64 Bit 133 MHz. The card is driven by a new high function, high performance ASIC. To ensure maximum

Pagina 410

40 DS8000 Series: Concepts and ArchitecturePrimary power suppliesThe DS8000 primary power supply (PPS) converts input AC voltage into DC voltage. The

Pagina 411

Chapter 2. Components 41Ethernet switchesIn addition to the Fibre Channel switches installed in each disk enclosure, the DS8000 base frame contains t

Pagina 412

42 DS8000 Series: Concepts and Architecture

Pagina 413

© Copyright IBM Corp. 2005. All rights reserved. 43Chapter 3. Storage system LPARs (Logical partitions)This chapter provides information about storage

Pagina 414

44 DS8000 Series: Concepts and Architecture3.1 Introduction to logical partitioningLogical partitioning allows the division of a single server into

Pagina 415

Chapter 3. Storage system LPARs (Logical partitions) 45Building blockA building block is a collection of system resources, such as processors, memory

Pagina 416

46 DS8000 Series: Concepts and ArchitectureFigure 3-1 Logical partitionSoftware and hardware fault isolationBecause a partition hosts an independen

Pagina 417

Chapter 3. Storage system LPARs (Logical partitions) 47allowing the on-demand allocation of those resources to different partitions and the managemen

Pagina 418

Contents v5.3 The abstraction layers for disk virtualization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 855.3.1 Array site

Pagina 419

48 DS8000 Series: Concepts and Architectureapplication on separate smaller partitions can provide better throughput than running a single large insta

Pagina 420

Chapter 3. Storage system LPARs (Logical partitions) 49Figure 3-2 DS8300 Model 9A2 - LPAR and storage facility imageThe DS8300 series incorporates

Pagina 421

50 DS8000 Series: Concepts and ArchitectureFigure 3-3 DS8300 LPAR resource allocationEach storage facility image has access to:򐂰 50 percent of the

Pagina 422

Chapter 3. Storage system LPARs (Logical partitions) 51Figure 3-4 Storage facility image resource allocation in the processor complexes of the DS83

Pagina 423

52 DS8000 Series: Concepts and ArchitectureRIO-G interconnect separationFigure 3-4 on page 51 depicts that the RIO-G interconnection is also split be

Pagina 424

Chapter 3. Storage system LPARs (Logical partitions) 53򐂰 An additional 256 DDMs – Up to 128 DDMs per storage facility imageThe second Model 9AE (expa

Pagina 425

54 DS8000 Series: Concepts and ArchitectureTable 3-1 Model conversions regarding LPAR functionality3.3 LPAR security through POWER™ Hypervisor (PH

Pagina 426

Chapter 3. Storage system LPARs (Logical partitions) 55Figure 3-6 LPAR protection - POWER Hypervisor3.4 LPAR and Copy ServicesIn this section we p

Pagina 427

56 DS8000 Series: Concepts and ArchitectureFigure 3-7 DS8300 storage facility images and Copy ServicesFlashCopyThe DS8000 series fully supports the

Pagina 428

Chapter 3. Storage system LPARs (Logical partitions) 57The hardware-based LPAR implementation ensures data integrity. The fact that you can create du

Pagina 429

vi DS8000 Series: Concepts and Architecture8.5.1 S-HMC network requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 430

58 DS8000 Series: Concepts and ArchitectureFigure 3-8 Example of storage facility images in the DS8300This example shows a DS8300 with a total phys

Pagina 431

Chapter 3. Storage system LPARs (Logical partitions) 59Figure 3-9 Comparison with ESS Model 800 and DS8300 with and without LPAR3.6 SummaryThe DS8

Pagina 432

60 DS8000 Series: Concepts and Architecture

Pagina 433

© Copyright IBM Corp. 2005. All rights reserved. 61Chapter 4. RASThis chapter describes the RAS (reliability, availability, serviceability) characteri

Pagina 434

62 DS8000 Series: Concepts and Architecture4.1 NamingIt is important to understand the naming conventions used to describe DS8000 components and con

Pagina 435

Chapter 4. RAS 63Figure 4-2 Dual image modeIn Figure 4-2 we have two storage facility images (SFIs). The upper server 0 and upper server 1 form SFI

Pagina 436

64 DS8000 Series: Concepts and ArchitectureReliability, availability, and serviceabilityExcellent quality and reliability are inherent in all aspects

Pagina 437

Chapter 4. RAS 65generate Early Power-Off Warning (EPOW) events. Critical events (for example, a Class 5 AC power loss) trigger appropriate signals f

Pagina 438

66 DS8000 Series: Concepts and ArchitectureFault maskingIf corrections and retries succeed and do not exceed threshold limits, the system remains ope

Pagina 439

Chapter 4. RAS 67A mechanism must exist to allow this sharing of resources in a seamless way. This mechanism is called the hypervisor. The hypervisor

Pagina 440

Contents vii10.3.1 Configuring a storage complex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21110.3.2 Configuring

Pagina 441

68 DS8000 Series: Concepts and Architecturedisk system. It is also checked by the DS8000 before the data is sent to the host in response to a read I/

Pagina 442

Chapter 4. RAS 69Figure 4-3 Normal data flowFigure 4-3 illustrates how the cache memory of server 0 is used for all logical volumes that are member

Pagina 443

70 DS8000 Series: Concepts and ArchitectureFigure 4-4 Server 0 failing over its function to server 1This entire process is known as a failover. Aft

Pagina 444

Chapter 4. RAS 71The single purpose of the batteries is to preserve the NVS area of server memory in the event of a complete loss of input power to t

Pagina 445

72 DS8000 Series: Concepts and ArchitectureFigure 4-5 Single pathed hostIt is always preferable that hosts that access the DS8000 have at least two

Pagina 446

Chapter 4. RAS 73Figure 4-6 Dual pathed hostSAN/FICON/ESCON switches Because a large number of hosts may be connected to the DS8000, each using mul

Pagina 447

74 DS8000 Series: Concepts and Architecture4.5.1 Open systems host connectionIn the majority of open systems environments, IBM strongly recommends t

Pagina 448

Chapter 4. RAS 75CUIR allows the DS8000 to request that all attached system images set all paths required for a particular service action to the offl

Pagina 449

76 DS8000 Series: Concepts and ArchitectureFigure 4-7 also shows the connection paths for expansion on the far left and far right. The paths from the

Pagina 450

Chapter 4. RAS 77RAID-10 theoryRAID-10 provides high availability by combining features of RAID-0 and RAID-1. RAID-0 optimizes performance by stripin

Comentarios a estos manuales