Action
Contact IBM technical support for assistance.
CMUN02296E SOURCE Unable to delete logical volume
Explanation
The storage management console server reports a storage unit microcode-level
error.
Action
Contact IBM technical support for assistance.
CMUN02297E SOURCE Unable to create logical volume: FB volumes must
have a data type.
Explanation
The specification for a fixed block logical volume does not contain a data type.
Fixed block logical volumes must have one of the following data types:
v 512-byte block
v 520-byte block unprotected
v 520-byte block protected
Action
Specify a data type, and then resubmit the task. If the problem persists, contact
IBM technical support for assistance.
CMUN02298E SOURCE Unable to create logical volume: FB volumes must
have an extent pool.
Explanation
The logical volume specification does not contain an extent pool. Fixed block logical
volumes must have an extent pool from which their extents are allocated.
Action
Specify an extent pool, and then resubmit the task. If the problem persists, contact
IBM technical support for assistance.
CMUN02299E SOURCE Unable to create logical volume: FB volumes must
have a requested capacity.
Explanation
The logical volume specification does not contain a requested capacity.
216 IBM TotalStorage DS8000: Messages Reference