0033-1049 0033-1054
0033-1049 digq() was unable to establish a communication channel to the
Performance Monitor. Error is
string
Explanation: The performance statistics query program, digq, was unable to establish a
communication channel to the Performance Monitor.
Error Class: The bind() function failed for the indicated reason.
User Response: Gather information about the problem and follow local site procedures for
reporting hardware and software problems.
0033-1050 digq() experienced a problem while waiting for input from the Performance
Monitor. Error is
string
Explanation: The performance statistics query program, digq, experienced a problem while
waiting for input from the Performance Monitor.
Error Class: The select() function failed for the indicated reason.
User Response: Gather information about the problem and follow local site procedures for
reporting hardware and software problems.
0033-1051 digq() experienced a problem accepting input from the Performance
Monitor. Error is
string
Explanation: The performance statistics query program, digq, experienced a problem while
waiting for input from the Performance Monitor.
Error Class: The accept() function failed for the indicated reason.
User Response: Gather information about the problem and follow local site procedures for
reporting hardware and software problems.
0033-1052 digq() was unable to read a message from the Performance Monitor.
Error is
string
Explanation: The Dig Query program unable to read message from Performance Monitor.
Error Class: The socket read() function failed for the indicated reason.
User Response: Gather information about the problem and follow local site procedures for
reporting hardware and software problems.
0033-1053 digq() was unable to send a message to either dig or the Performance
Monitor in
string
Error is
string
Explanation: The digquery encountered a error when communicating with the
Dig/Performance Monitor program.
Error Class: The socket write() function failed for the indicated reason.
User Response: Gather information about the problem and follow local site procedures for
reporting hardware and software problems.
0033-1054 digq()::p;oadcast: Unable to get the socket interface configuration.
Error is
string
Explanation: The performance statistics query program, digq, was unable to get the
interface configuration of the socket in order to locate broadcast devices.
Error Class: The ioctl() function failed for the indicated reason.
User Response: Gather information about the problem and follow local site procedures for
reporting hardware and software problems.