IBM System x3950 X6 15
The following rules apply when building a server configuration with eXFlash DIMMs:
The 200 GB and 400 GB eXFlash DIMMs cannot be mixed.
RAID 1 mirroring is provided by the eXFlash DIMM device driver.
Performance memory mode must be selected. RAS (lockstep) memory mode is not supported.
Only RDIMMs are supported by eXFlash DIMMs; LRDIMMs are not supported
eXFlash DIMMs can only installed on the Compute Books in the lower half of the server (processors
1-4)
The maximum quantities of eXFlash DIMMs are as follows:
Four processors: 16 eXFlash DIMMs
o
Six processors: 24 eXFlash DIMMs
o
Eight processors: 32 eXFlash DIMMs
o
Internal storage
The server supports 1.8-inch solid-state drives in the IBM eXFlash SSD units and 2.5-inch SSDs and
HDDs. Drives are installed in the Storage Book. The x3950 X6 has two Storage Books. The Storage Book
supports the following configurations:
4x 2.5-inch hot-swap drive bays
8x 2.5-inch hot-swap drive bays
4x 2.5-inch hot-swap drive bays + 8x 1.8-inch hot-swap SSD bays
8x 1.8-inch hot-swap SSD bays
16x 1.8-inch hot-swap SSD bays
The following figure shows these configurations.
Figure 6. Internal drive configurations