Ibm Netcool/OMNIbus Probe for Nortel CNM Manual de usuario

Busca en linea o descarga Manual de usuario para Hardware Ibm Netcool/OMNIbus Probe for Nortel CNM. IBM Netcool/OMNIbus Probe for Nortel CNM User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 34
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
SC23-6398-02
IBM
Netcool/OMNIbus Probe for Nortel CNM
1.0.3744
frontmatter.fm December 22, 2007
Reference Guide
Publication Date: December 22, 2007
Vista de pagina 0
1 2 3 4 5 6 ... 33 34

Indice de contenidos

Pagina 1 - Reference Guide

SC23-6398-02IBMNetcool/OMNIbus Probe for Nortel CNM1.0.3744 frontmatter.fm December 22, 2007Reference GuidePublication Date: December 22, 2007

Pagina 2

Netcool/OMNIbus Probe for Nortel CNM Reference Guide4Data acquisitionThe Probe for Nortel CNM gathers events from the Nortel CNM 3GPP servers using a

Pagina 3 - Contents

Probe for Nortel CNM 5The FTP command is run in the user’s home directory. For FTP users other than root, you must change the default path specified b

Pagina 4

Netcool/OMNIbus Probe for Nortel CNM Reference Guide6Filtering notifications and alarmsThe NotificationFilter and AlarmFilter properties allow you to

Pagina 5 - Document control page

Probe for Nortel CNM 7Command line interfaceThe Probe for Nortel CNM is supplied with a command line interface (CLI). This interface allows you to per

Pagina 6

Netcool/OMNIbus Probe for Nortel CNM Reference Guide8Note: Since the CLI is based upon telnet connections, you can connect to the probe from anywhere

Pagina 7 - Probe for Nortel CNM

Probe for Nortel CNM 9Peer-to-Peer failover functionalityThe Probe for Nortel CNM supports failover configurations where two probes run simultaneously

Pagina 8

Netcool/OMNIbus Probe for Nortel CNM Reference Guide10Internationalization supportThe Probe for Nortel CNM supports multi-byte character sets. To vie

Pagina 9 - Basic configuration

Probe for Nortel CNM 11Properties and command line optionsTable 5 describes the properties and command line options specific to this probe. For inform

Pagina 10 - Data acquisition

Netcool/OMNIbus Probe for Nortel CNM Reference Guide12CommandPort integer-commandport integerSpecifies the port to which users can telnet to communic

Pagina 11 - Timeout

Probe for Nortel CNM 13Password string -password string Password required with the Username property to log in to the system.The default is "&quo

Pagina 12

This edition applies to 1.0.3744 of Netcool/OMNIbus Probe for Nortel CNM (SC23-6398-02) and to all subsequent releases and modifications until otherw

Pagina 13 - Command line interface

Netcool/OMNIbus Probe for Nortel CNM Reference Guide14TimeTick integer -timetick integer Time (in minutes) that the Notificiation IRP session remains

Pagina 14

Probe for Nortel CNM 15ElementsTable 6 describes the elements generated by the Probe for Nortel CNM.Table 6. Elements (1 of 2)Element name Element des

Pagina 15

Netcool/OMNIbus Probe for Nortel CNM Reference Guide16NV_CORRELATED_NOTIFICATIONS_notif_ID_SetSet of notifications to which this notification is cons

Pagina 16 - Internationalization support

Probe for Nortel CNM 17Error messagesTable 7 describes the error messages specific to this probe. For information about generic error messages, see th

Pagina 17

Netcool/OMNIbus Probe for Nortel CNM Reference Guide18BAD_PARAM Exception i.e one or more of the in/out parameter is nullInvalidParameter ExceptionNe

Pagina 18

Probe for Nortel CNM 19Error to parse event completelyFailed to parse event completelyName is null, cannot create ElementNetcoolIRPManager: Category V

Pagina 19

Netcool/OMNIbus Probe for Nortel CNM Reference Guide20NetcoolIRPManager: Failed to retrieve EntryPointIRP object from security interface:The probe ha

Pagina 20

Probe for Nortel CNM 21ProbeWatch messagesTable 8 describes the raw ProbeWatch error messages that the probe generates. For information about generic

Pagina 21 - Elements

Netcool/OMNIbus Probe for Nortel CNM Reference Guide22Failed to log in to the Nortel Security IRP - incorrect username/passwordFailed to log in to in

Pagina 22

Probe for Nortel CNM 23SYNCHRONIZATION FAILEDThe probe could not get new alarms.The probe failed to get the alarm list, or failed to perform resynchro

Pagina 23 - Error messages

iiiContentsDocument control page. . . . . . . . . . . . . . . vProbe for Nortel CNM . . . . . . . . . . . . . . . . . 1Summary . . . . . . . . . . .

Pagina 24

Netcool/OMNIbus Probe for Nortel CNM Reference Guide24

Pagina 25

25appnotices.f m December 22, 2007Appendix A. NoticesThis appendix contains the following:• "Notices" on page 25• "Trademarks" on

Pagina 26

Netcool/OMNIbus Probe for Nortel CNM Reference Guide26LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTIC

Pagina 27 - ProbeWatch messages

Appendix A. Notices 27Any performance data contained herein was determined in a controlled environment. Therefore, the results obtained in other opera

Pagina 28

Netcool/OMNIbus Probe for Nortel CNM Reference Guide28

Pagina 29

Netcool/OMNIbus Probe for Nortel CNM Reference Guideiv

Pagina 30

vdocscontrol.fm December 22, 2007Document control pageThe Netcool/OMNIbus Probe for Nortel CNM documentation is provided in softcopy format only. To o

Pagina 31 - Appendix A. Notices

Netcool/OMNIbus Probe for Nortel CNM Reference Guidevi

Pagina 32

Probe for Nortel CNM 1Nortel CNM.fm December 22, 2007Probe for Nortel CNMNortel CNM (CDMA Network manager) is a networking and service management syst

Pagina 33 - Trademarks

Netcool/OMNIbus Probe for Nortel CNM Reference Guide2SummaryTable 2 provides a summary of the Probe for Nortel CNM.Table 2. SummaryProbe target Norte

Pagina 34

Probe for Nortel CNM 3Supported platformsFor details of the versions of HP-UX and Solaris on which this probe is supported, see the following page on

Comentarios a estos manuales

Sin comentarios